CytoTox-Glo™ Cytotoxicity Assay
Measure Relative Dead Cell Number with Proven Luminescent Technology
The CytoTox-Glo™ Assay is a luminescent cytotoxicity assay that measures the relative number of dead cells in cell populations. The assay measures the extracellular activity of a distinct intracellular protease activity (dead-cell protease) when the protease is released from membrane-compromised cells. A luminogenic cell-impermeant peptide substrate (AAF-aminoluciferin) is used to measure dead-cell protease activity. The liberated aminoluciferin product is measured as "glow type" luminescence generated by Ultra-Glo™ Recombinant Luciferase provided in the assay reagent. The AAF-aminoluciferin substrate cannot cross the intact membrane of viable cells and does not generate any appreciable signal from the live-cell population. The amount of luminescence directly correlates with the percentage of cells undergoing cytotoxic stress.
With the addition of a lysis reagent (provided), the CytoTox-Glo™ Assay also can deliver the luminescent signal associated with the total number of cells in each assay well. Viability can be calculated by subtracting the luminescent dead-cell signal from the total luminescent value, thus allowing you to normalize assay data to cell number and mitigate assay interferences that may lead to erroneous conclusions. The cytotoxicity protease biomarker is constitutive and conserved across cell lines, and the CytoTox-Glo™ Assay demonstrates excellent correlation with other methods of assessing cell viability.
Highly Sensitive
The CytoTox-Glo™ Assay detects small changes in viability because of its high sensitivity. This graph shows the superior signal-to-noise ratios of the CytoTox-Glo™ Assay compared to a fluorescent LDH assay. Detects as few as 200-500 cytotoxic cells in a total population of 10,000 cells and less than 10 cytotoxic cells in a limiting dilution series.
More Reliable Data
Determining cytotoxicity and viability by lysis. The luminescent signal collected after lysis was adjusted to reflect the "live cell" contribution by subtracting the initial dead cell signal. The data above are plotted as "dead cell" or "live cell" signal versus the concentration of calcium ionophore.
Notes
Using 100μl/assay in a 96-well plate format, Cat.# G9290 is sufficient to perform 100 assays; Cat.# G9291, 500 assays; Cat.# G9292, 1,000 assays. Using 25μl per well in a 384-well plate format, Cat.# G9290 is sufficient to perform 400 assays; Cat.# G9291, 2,000 assays; Cat.# G9292, 4,000 assays.
Protocols
Specifications
Catalog Number:
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
Assay Buffer |
G146A | 2 × 5ml |
AAF-Glo™ Substrate |
G607A | 1 × 1 bottle |
|
Digitonin |
G944A | 1 × 40μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
Assay Buffer |
G146A | 10 × 5ml |
AAF-Glo™ Substrate |
G607A | 5 × 1 bottle |
|
Digitonin |
G944B | 1 × 175μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box?
| Item | Part # | Size |
|---|---|---|
|
Assay Buffer |
G146B | 4 × 25ml |
|
AAF-Glo™ Substrate |
G607B | 2 × 1 bottle |
|
Digitonin |
G944B | 2 × 175μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Resources
No related resources available
Related Products
Similar Products
LDH-Glo™ Cytotoxicity Assay
Bioluminescence-based LDH assay for sensitive detection of cytotoxicity in samples low in cell number, including 3D microtissues.
J2380, J2381
CytoTox-Fluor™ Cytotoxicity Assay
A single-reagent-addition, homogeneous, fluorescent assay that measures the relative number of dead cells in cell populations.
G9260, G9261, G9262
CellTox™ Green Cytotoxicity Assay
Measures changes in membrane integrity. Kinetically monitors cytotoxicity up to 72 hours with multiplex capability.
G8741, G8742, G8743, G8731
CytoTox-ONE™ Homogeneous Membrane Integrity Assay
A homogeneous, LDH-based fluorometric method for quantifying non-viable cells.
G7890, G7891, G7892
Frequently Used With
MultiTox-Fluor Multiplex Cytotoxicity Assay
A single-reagent-addition fluorescent assay that measures the number of live and dead cells in culture wells.
G9200, G9201, G9202
Caspase-Glo® 3/7 Assay System
An easy-to-use, plate-based luminescent assay for detecting caspase-3/7 activity.
G8090, G8091, G8093, G8092
Viral ToxGlo™ Assay
A quantifiable method of determining viral-induced cytopathic effects (CPE) in host cells caused by lytic virions.
G8941, G8942, G8943
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000